Please see notes below on guidelines for shipping tubes and plates

If you are submitting this...

Then submit in this...
...

For this platform...

GSAF requests this amount...

Minimum recommended amount

In this volume...

Finished NGS sequencing librariesAll Final libraries must be in 1.5 ml tubesIllumina NovaSeq, NextSeq, MiSeq, or iSeq
20 ul @ >2 nM
>2nM≥20ul
DNA or RNA for QC1.5 ml tubes
BioAnalyzer QC or Qubit10 ul > 1 ng/ul4 ul > 50 pg/ul  
Bioanalyzer-DNA>50pg/ul3-5ul
Bioanalyzer-RNA Nano

25-500ng/ul (Total RNA)

25-250ng/ul (mRNA)

Bioanalyzer-RNA Pico

.05-5ng/ul (Total RNA)

.25-5ng/ul (mRNA)

Bioanalyzer-small RNA

1-100ng/ul (Total RNA)

1-20ng/ul (enriched small RNA)

DNA - genomic DNA (NOTE: this assumes PURE POPULATIONS - i.e. 100% bacterial or fungal - you may need to assay samples with mixed populations prior to submission)96-well plates
unless
*, or 1.5mL tubes if  you are submitting
12 or less
≤12 samplesMetagenomics (bacterial or fungal)
25 ul @ 10 ng
10ng/ul FOR ALL SAMPLES SUBMITTED (i.e. customer
must
MUST normalize input samples)
25 ul @ 1 ng/ul  
≥25ul
DNA - genomic DNA, high molecular weight, for library prep1.5 ml tubes, or 96-well plate for 12 or more samples*
Any platform, fragment library2 ug @ > 20 ng/ul   (At least 25 ul's)
DNA library prep, Covaris fragmentation1-80ng/ul≥25ul
100 ng @ > 5 ng/ul 
DNA fragments (including IP-derived DNA) or DNA amplicons (PCR products), for library prep1.5 ml tubes, or 96-well plate for 12 or more samples*
Any platform100 ng @ > 1 ng/ul  (At least 25 ul's)200 ng @ > 50 pg/ul  
DNA library prep1-80ng/ul≥25ul
RNA
RNA*
- total RNA, for library prep**1.5 ml tubes, or 96-well plate for 12 or more samples
Any platform (Poly-A or Ribosomal Depletion
*RNA-seq, PolyA purification10-80ng/ul≥25ul
RNA-seq, Ribosomal Depletion 2-80ng/ul≥25ul
RNA-Seq,
TagSeq)2 ug @ > 40 ng/ul, RIN>7   (At least 50 ul's)500 ng @ > 10 ng/ul  
no removal or enrichment1-200ng/ul≥15ul
TagSeq10-100ng/ul (samples MUST be normalized within this range)≥25ul
RNA-mRNA, for library prep1.5 ml tubes, or 96-well plate for 12 or more samples*RNA-Seq.2-20ng/ul≥15ul
RNA-
RNA* - mRNA,
miRNA or other RNA sub-fractions, for library prep1.5 ml tubes, or 96-well plate for 12 or more samples
Any platform500 ng @  25 ng/ul   (At least 25 ul's)
*Small RNA library prep

20-200ng/ul(Total RNA)

2-20ng/ul (purified small RNA)

≥15ul

* Samples should be plated starting at A1 then plate the samples vertically, A1 to H1, then A2 to H2 and so on.....Do not skip wells, you will be charged for wells that are skipped and we will not process samples that are plated A1 to A12.

** RNA must be free of DNA

50 ng @ > 2 ng/ul  

Sample storage solutions

DNA or RNA can be provided in water, TE, low-TE, or other common storage solutions. If you are submitting your sample in something other than water or TE, please note this in either the Sample Description or Brief Job Description fields.

...